S Series – Fire Test Report
This report confirms that S Series Interior Film was tested by the Flame Proof Institute and meets national fire safety standards, demonstrating fire-retardant performance suitable for interior applications.
B Series – Fire Retardant Test Certificate
This document confirms that B Series (Bodaq Interior Film) has been independently tested by MPA NRW and meets the B1 fire-retardant standard (DIN 4102-1), certifying it as flame-resistant for safe use in interior applications.
3M DI-NOC – Flammability Test Report (AS 1530)
Fire hazard indices for metallic DI-NOC film under Australian Standard 1530.3.
3M DI-NOC – Fire Hazard Test Report (AS 5637)
Confirms 3M DI-NOC achieves Group 1 classification under Australian fire standards.
B Series – Contamination Resistance Test Report
Demonstrates resistance to staining and damage from everyday substances.
B Series – Antimicrobial Activity Test Report
Tests effectiveness against bacteria such as Staphylococcus aureus and E. coli.
B Series – Adhesive Strength Test Report
Confirms adhesive strength for a reliable surface bond.
B Series – Abrasion Resistance Test Report
Tests durability against wear and abrasion over 1000 cycles.
B Series – Tensile Strength Test Report
Demonstrates durability through tensile strength testing.
B Series – Right-Angle Tear Load Test Report
Assesses the tear resistance of the film as a measure of product strength.
B Series – Resistance to Heat Test Report
Tests dimensional stability under heat exposure, ensuring the film maintains its form.
B Series – Phthalate Content Test Report
Confirms film is free from harmful phthalate plasticisers, safe for indoor use.
B Series – Pencil Hardness Test Report
Confirms scratch resistance with a 3H pencil hardness rating.
B Series – Heavy Metal Content Test Report
Confirms absence of brominated flame retardants and harmful heavy metals.
B Series – Gas Toxicity Test Report
Assesses gases released during fire exposure to evaluate toxicity.
B Series – Elongation at Break Test Report
Tests flexibility and stretch capacity before breaking point.
LX Hausys – L Series UL Test Report (2009)
Provides detailed fire test data supporting the UL Certification, including surface burning characteristics.
LX Hausys – L Series RoHS Test Report (2020)
Confirms the film is free from restricted substances such as lead, mercury and cadmium in compliance with the European RoHS Directive.
LX Hausys – L Series REACH Test Report (2020)
Verifies compliance with the European REACH regulation by testing for Substances of Very High Concern (SVHC).
LX Hausys – L Series SGS Railway Test Report (2019)
Confirms L Series Interior Film meets fire safety standards for use in railway vehicle interiors in India.
B2 Fire Test Report
Initial German DIN 4102-1 assessment of L Series Interior Film, testing performance for potential B2 fire classification.
B1 Fire Test Report
Full German DIN 4102-1 classification. Confirms L Series Interior Film is “hardly flammable” (Class B1) when applied to steel.
B Series – Environmental Hazards Test Report
Confirms B Series Interior Film contains no harmful heavy metals such as lead, cadmium, chromium or mercury.